Call Today


 
 

Valve Networking

Profibus DP Position Monitoring

Main Product Info
Manufacturer: Moniteur Devices 
Description:
Moniteur VPCs with encapsulated Profibus
interface cards adapt your on/off automated valves to an advanced Profibus DP valve network. The Profibus protocol was developed in 1989 by a group of factory automation suppliers.

Profibus-DP is a device level bus that supports both analog and discrete signals. Profibus-DP has widespread usage for such items as remote I/O systems, motor control centers, and variable speed drives. Profibus-DP communicates at speeds from 9.6 Kbps to 12 Mbps over distances from 100 to 1,200 meters.

Moniteur's Advanced Profibus Platform Improves Reliability
The Network Card. A full function encapsulated network card includes the following benefits:
Encapsulated electronics and position sensors ensure reliability in corrosive, humid and dirty environments.
Hall effect position sensors designed for the card and provide optimum stability in
areas of high vibration.
Two transistor outputs with a combined output of 4.8w @ 24VDC are available for your solenoid valves and allow many standard DC NAMUR valves to be used, avoiding special "low power" valves
High visibility LEDs are located on-board for local indication of on -board sensors, auxiliary inputs, outputs and network state.
Two additional inputs are optional for local pressure or temperature switches.
The Enclosure Platform. Moniteur's platform is available in a wide variety of enclosure materials to match your hazardous or corrosive environment and is designed to provide long-term reliability.
Housings in Aluminum or SuperTough Zytel Thermoplastic for General Purpose or Hazardous Areas
Moniteur’s patented Loc-Ring Cam and Shaft Retention System ensures sensing accuracy and a multi-million cycle life of the physical platform.
DIN 4-pin Female Micro or 5-pin Mini plug connectors can be fitted to the conduit entries of the enclosures to speed installation in general purpose areas.
Moniteur's industry-preferred indicator has a rated minimum life of 1,000,000 cycles. With indicators still in service after 9 million cycles, you're assured of long-term reliability.
Profibus DP Technical Information

Each network supports up to 32 devices per segment or 64 with repeaters

Automatic baud rate up to 500K bit/sec.
Up to 1000m maximum trunk length w/o repeaters
Supports both discrete and analog signals
I/O modules allow connection of conventional analog and discrete devices
Interfaces available for many variable speed drives, motor control centers, and field devices
Supports 32 devices per segment, 62 with repeaters
Simple integration of new devices to an existing network
Supports mono-master and multi-master systems
Intelligent Part Number System - Specify Your Profibus DP Valve Monitor

A

M

Y

B

-

5

S

2

0

-
DP7

1

2

3

4

-

5

6

7

8

1 - Enclosure Type


4 - Bearing


Ex-proof Nema 7,9 Aluminum

A

Bronze

B

General Purpose Aluminum Nema 4
F

303 Stainless

S

Zytel Thermolastic Nema 4
R

5 - Shaft


2 - Cover


Standard 303 SS

1

With Moniteur

M

Standard 316 SS

3

Flat Cover

F

NAMUR 303 SS

5

3 - Moniteur


NAMUR 316 SS

7

No Indicator

N

LONG NAMUR 303 SS

E

Black / Yellow

Y

LONG NAMUR 316 SS

G

3-way path O

O

6 - Switch Type


3-way path T

T

On Board Hall Effect Sensors

S

3-way path F

F

7 - Sensor Quantity

2

4-way path S

S

2

2

180 degree T

1

8 - Conduit


Green / White

G

(2) F 3/4" NPT (A)

0

Red / White

R

(2) F 3/4" + (1) F 1/2" NPT (A)

6

Blue / White

B

(2) F 1/2" NPT (F, R)

0

Green / Red

A

(3) F 1/2" NPT (F, R)

6

Red / Green

C

Network Card


   

Profibus DP, 2 Transistor Outputs

-DP7

Additional Advantages of In-Plant Networking

Drastically Reduced Installation Costs - Wiring and installation time are reduced, yielding a cost saving up to 40% versus conventional methods.

Reduced Maintenance Costs and Increased System Reliability - Components require less maintenance and are designed to work "one way" only. Built-in diagnostic functions allow components to be continuously monitored.

Faster Start-Up - Set-up is simpler and diagnostic functions speed troubleshooting.

Simplified Plant Wiring - Automated valves can be inter-connected in any configuration. Utilizing 4 wires eliminates wiring "spaghetti" of older schemes.

 

 
Ask A Question
Name:
Phone:
Email:
Comments or Questions
Specialty Valve & Controls has made a great difference in the operation of our facility. The performance of products ...
Bill David

Site Usage Policy 

Specialty Valve & Controls | 3001 Griffith Street, Charlotte, NC 28203 | Phone 704-522-9873, Fax 704-522-9875

© 2012 Specialty Valve & Controls | Admin | Site by Paradigm