Call Today


 
 

Valve Position Transmitters

Guardian Linear VPT

Main Product Info
Manufacturer: Moniteur Devices 
Applications: Approvals: UL / CSA Approved for Class 1, Division 2 Groups A, B and Class 1, Division 1 Groups C-D and Class 2, Division 1 Groups E, F, G with TTL SPDT Non-Contact Switches. 
Description:

Explosion-Proof Nema 4, 4x, 7 & 9
The GUARDIAN is a unique valve position transmitter designed for both linear and rotary valves. The picture at left shows the GUARDIAN mounted to a typical linear control valve. The Guardian can also be used on a rotary valves for NEMA 6P (partial submersion) applications. With both UL and CSA approvals, the Guardian is the clearly the superior choice.

Features & Benefits of Moniteur's Guardian VPT
Available with Moniteur's reliable line of TTL Non-Contact Switches or Inductive Sensors to inferface with any plant control system
Internal Switches and terminal block are labeled for easier installation.
Intelligent Part Number System - Specify Your Grardian

K

F

N

N

-

0

2

2

6

1

2

3

4

-

5

6

7

8

1 - Series

6 - Switch Type

Guardian
K
Non-Contact (Proximity)

2 - Cover

Tungsten TTL SPDT - 3A
2
Flat Cover
F
Rhodium TTL SPDT- 1A
T
3 - Moniteur

Bifurcated TTL SPDT- 3A
B
no Indicator
N
Inductive Sensors

4 - Bearing / Inserts

P&F (NAMUR)
8
no bearing
N
7 - Switch Quantity

5 - Shaft

1-2
1-2
no shaft
0
8 - Conduit



(2) F 3/4" + (1) F 1/2" NPT
6


(2) F 3/4 " + (1) M 1/2" NPT
8
 

Most common items available for quick delivery:

KFNN-0216

KFNN-0226

KFNN-0T16

KFNN-0T26

Moniteur Switch and Sensor Selection Guide
Non-Contact TTL SPDT (proximity-type) Switches
These hermetically sealed switches set the standard for reliability. Tungsten TTL switches are used for high current AC and DC applications with a rating of 3A at 120 VAC and 2A at 24 VDC. Choose Rhodium TTL for low voltage / low current DC and Intrinsically Safe applications. Optional LEDs are also available on the Krystal TTL with Rhodium contacts. NOTE: Switches with Tungsten contacts are not recommended for DC signals lower than 50 mA. Specifications
NAMUR, PNP or NPN Inductive Sensors

A wide variety of industry standard sensors is available to interface with control systems found in today's modern process plants. Specifications

 

 
Ask A Question
Name:
Phone:
Email:
Comments or Questions
I've used Specialty Valve & Controls since 1995. Their service is unmatched.
Evan Jacobson

Site Usage Policy 

Specialty Valve & Controls | 3001 Griffith Street, Charlotte, NC 28203 | Phone 704-522-9873, Fax 704-522-9875

© 2012 Specialty Valve & Controls | Admin | Site by Paradigm